JACKETING AND INSULATING TAPES
PLYTUFF - F/R PVC Jacketing Tape
PVC tape specifically formulated for flame resistance and abrasion resistance. Use for repairing nicks and tears in all mining cables. Use this tape for primary insulation through 600V. Ideally suited for securing premolded and shrinkable sleeve ends to the cable jacket. Title 30-CFR 18.64, P-153-MSHA Acceptance.
Product specificationsGLF® Jacket Repair Wrap
Use as a jacket repair or conduit repair when severe conditions tear or puncture the original cable jacket or conduit. Extremely abrasion-resistant, with excellent moisture exclusion properties. Approved under 30 CFR 7.404, approval number P-7K-SK-153082-1-MSHA. GLF2 has.
Product specifications
NEW! GLF2® Jacket Repair Wrap
Is our newest laminate of a specially formulated Hypalon backing and 2 flameretardant mastic layers possessing the superior abrasion and moisture resistance required for all types of cable jacket repair. The laminate is easy to apply and remains flexible at low temperatures. GLF 2 will adhere to all types of cable jackets yielding a positive moisture seal. FLF 2 bears the acceptance no. P-7K-SK-153082-1-MSHA.
Product specifications
L969 Fire-Resistant Insulating Tape (Linerless Rubber)
Use to insulate around the connector area on splices from 600V-69kV. Also used to fill in irregularities and to smooth out the splice profile before applying jacketing tape.
Product specifications
Rubber Mastic (RM) Tapes
A self-bonding mastic tape consisting of an ethylene propylene rubber (EPR) backing, bonded to a tacky, temperature stable, electrical grade mastic. Use for insulating and moisture sealing splices and terminations on solid dielectric cable. Can be wrapped, stretched or molded around irregular shapes for insulation build-up, water-sealing, and surface protection. Provides excellent electrical properties, superior adhesion, moisture and chemical resistance. For primary insulation up to 2kV.
Product specifications
TRAILING CABLE SPLICE KITS
GLF® Trailing Cable Splices
Use to construct a full or partial splice in single or multi-conductor portable mining cable. Four kits cover the entire range of splicing needs from 600 volt to 5kV, up to 500 KCM (connectors not included). All GLF splice kits meet the technical requirements set forth in 30-CFR § 7.404. Approval number P-7K-SK-153082-1-MSHA.
Product specifications
GLF2® Trailing Cable Splices
Product specificationsHIGH VOLTAGE SPLICES AND TERMINATION KITS
MINE POWER FEEDER Splice Kit
Use for splicing single and multi-conductor cable to 15kV found in the mine and prep plant. Kits contain all components to construct an electrically sound splice. The splice utilizes F/R Plyvolt linerless EPR insulating tape, which provides void-free build-ups, high dielectric strength, low electrical loss, and corona resistant. Emergency overload rating of 130°C. Connectors not included.
Product specifications
MINE POWER FEEDER Termination Kit
Use for terminating Mine Power Feeder cables through 15kV. Each kit will terminate a three core type GGC, shielded power cable common in mining operations. Also, ideally suited for motor lead terminations. Each kit contains three rolls of Stress-Wrap voltage gradient material, three ground connectors, three 24" (0,6m) ground ribbons, cleaning solvent and a fine grit cloth. Stress-Wrap is a laminate of EPR High Voltage Insulating Tape and a special voltage gradient stress-relieving compound. Terminal connector not included. U.S.Patent #4,187,389.
Product specifications
MINE TERMINAL WRAP
Use for terminating three-core shielded cables to 25 kV when installing a coupler. Each kit contains three rolls of specially formulated Stress-Wrap. Packaged on 1" (25mm) wide coreless rolls. Stress-Wrap is a laminate of EPR High Voltage InsulatingTape and a special voltage gradient stress-relieving compound. U.S. Patent #4,187,389.
Product specifications